BPBSH - CITGO NO 93423, 10W MILITARY

  • MSDS: BPBSH
  • Manufacturer: CITGO PETROLEUM CORP
  • Product Name: CITGO NO 93423, 10W MILITARY
  • National Stock Number: 9150-00-186-6668
Product Identification

Product ID:CITGO NO 93423, 10W MILITARY
MSDS Date:05/17/1991
FSC:9150
NIIN:00-186-6668
MSDS Number: BPBSH

Responsible Party
CITGO PETROLEUM CORP
6100 S YALE BLDG 1 WARREN PL
TULSA, OK 74102
US

Emergency Phone: 318-491-6215, CHEMTREC 800-424-9300

Info Phone: 918-495-5933

Cage: 7X110

Contractor
CITGO PETROLEUM CORP
3758 TULSA, OK 74102 US

Telephone: 918-495-5933

Cage: 7X110

Ingredients

CAS #

CAS: 64741-88-4

Fraction By Weight: 75-90%

OSHA PEL 5 MG/M3 (OIL MIST)

ACGIH TLV: 5 MG/M3 (OIL MIST)


PETROLEUM OIL, THIS ING. IS A PART OF THE MIXTURE OF ING.

CAS: 64741-89-5

RTECS: PY8041500

OSHA PEL 5 MG/M3 OIL MIST

ACGIH TLV: 5 MG/M3 OIL MIST


POUR DEPRESSANT

Fraction By Weight: < 1%

Hazards

LD50 LC50 Mixture:LD50 (ORAL RAT) IS > 5,000 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE-EYES:PRACTICALLY
NON-IRRITANT.SKIN: TRANSIENT,SLIGHT IRRITATION.INHALATION:LOW RISK
AT AMBIENT TEMPERATURES. MISTS/FUMES MAY CAUSE
DIZZINESS,HEADACHE,RESPIRATORY IRRITATION/CHEMICAL PNEUMONITIS.
INGESTION:LOW TOXICITY.AT A SAYBOLT VISCOSITY OF 220SUS(100F), LOW
ASPIRATION RISK.LARGE DOSE->DIARRHEA.CHRONIC-DRY SKIN
Explanation of Carcinogenicity:PRODUCT CONTAINS NO INGREDIENTS
CURRENTLY CLASSIFIED AS CARCINOGENIC BY NTP, IARC OR OSHA.
Effects of Overexposure:FUMES MAY CAUSE DIZZINESS, HEADACHE, NAUSEA,
RESPIRATORY IRRITATION, OR CHEMICAL PNEMONITIS. INGESTION OF LARGE
QUANTITIES MAY CAUSE SLIGHT GI DISCOMFORT, DIARRHEA, HEADACHE,
SUBCUTANEOUS OR INTRAMUSC ULAR INJECTION MAY CAUSE IRRITATION,
ERTHEMA, EDEMA.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION: REMOVE FROM EXPOSURE TO INCIDENTAL FUMES AND
PROVIDE RESPIRATORY SUPPORT IF NECESSARY. DERMAL: WASH WITH SOAP
AND WATER. EYES: FLUSH WITH LARGE AMOUNTS OF WATER. INGESTION:
INDUCE VOMITING AND SEEK MEDICAL AID. INJECTION: SEEK MEDICAL AID.

Fire Fighting

Flash Point Method:COC
Flash Point:450F,232C
Lower Limits:NOT KNOWN
Upper Limits:NOT KNOWN
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
CHEMICAL. DO NOT POINT WATER STREAM DIRECTLY INTO BURNING OIL.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:USE OF WATER OR FOAM MAY CAUSE FROTHING.

Accidental Release

Spill Release Procedures:REMOVE SOURCES OF HEAT/IGNITION.PROVIDE
ADEQUATE VENTILATION.TAKE UP SMALL SPILLS WITH NONCOMBUSTIBLE
ABSORBENT(FULLERS EARTH/SAND).PLACE INTO CONTAINERS.LARGE
SPILLS:CONTAIN SPILL IN EARTHEN DIKES FO R LATER RECOVERY.REPORT
SPILLS AS REQUIRED.
Neutralizing Agent:NOT APPLICABLE.

Handling

Handling and Storage Precautions:STORAGE-STORE IN A COOL,WELL
VENTILATED AREA.AVOID INHALATION & SKIN CONTACT ESPECIALLY WHEN
HANDLING USED OIL.
Other Precautions:AVOID CONTACT WITH EYES/SKIN.REPEATED CONTACT WITH
USED OIL CAUSED CANCER IN LABORATORY ANIMALS.WASH HANDS WITH SOAP
AND WATER AFTER HANDLING.REMOVE SOILED CLOTHING.AVOID BREATHING
MISTS/VAPORS.

Exposure Controls

Respiratory Protection:CONCENTRATION-IN-AIR DETERMINES PROTECTION
DEEDED. WEAR APPROVED ORGANIC VAPOR RESPIRATOR SUITABLE FOR OIL
MIST IN AREAS WITH SUFFICIENT OXYGEN.PROTECTION USUALLY NOT NEEDED
UNLESS PRODUCT IS HEATED O R MISTED.
Ventilation:VENTILATE AS NEEDED TO COMPLY WITH EXPOSURE LIMIT.
Protective Gloves:NITRILE
Eye Protection:SPLASH PROOF CHEMICAL GOGGLES
Other Protective Equipment:EYE WASH STATION.BODY-COVERING WORK CLOTHES
TO AVOID PROLONGED EXPOSURE.LAUNDER SOILED WORK CLOTHES BEFORE
REUSE.
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES. DO NOT WEAR CONTAMINATED CLOTHING OR
FOOTWEAR.
Supplemental Safety and Health
NOTE TO PHYSICIAN: FOLLOWING INGESTION, AT A SAYBOLT VISCOSITY OF ABOUT
187 AT 100F, THE RISK OF ASPIRATION INTO THE LUNGS IS REDUCED. FOR
QUANTITIES ABOVE 1 OUNCE, EMESIS OR LAVAGE MAY BE CONSIDERED.
SUBCUTANEOUS INJECTION REQUIRES PROMPTSURGICAL DEBRIDEMENT. IF NOT
FAMILIAR WITH TECHNIQUE, SEEK SKILLED ADVICE.

Chemical Properties

HCC:V4
Boiling Pt:B.P. Text:650F,343C
Vapor Pres:< 0.001
Vapor Density:>1
Spec Gravity:0.89
Evaporation Rate & Reference:<1 (N-BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:DARK AMBER FLUID, MILD ODOR
Percent Volatiles by Volume:NEGLIG

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS, STRONG ACIDS, CAUSTICS.
Stability Condition to Avoid:EXCESSIVE HEAT, OPEN FLAMES, FORMATION OF
OIL MIST
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE AND
TRACES OF OXIDES OF SULFUR, PHOSPHOROUS, ZINC, MAGNESIUM AND
CALCIUM.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH ALL APPLICABLE
FEDERAL, STATE AND LOCAL LAWS AND REGULATIONS. DO NOT FLUSH TO
DRAIN/SEWER. CONTACT THE AUTHORIZED DISPOSAL SERVICE.AVOID
LANDFILLING OF LIQUIDS. RECLAIM WHER E POSSIBLE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.